Crosby Straightpoint Wireless Base Station

SKU: GRRR218 Category:

Videos

Wireless Base Station

ModelStock No.Required Power SupplyOperational CurrentOutput Radio FrequencyMaximum Number of LoadcellsRange (ft)Operating TemperatureDimensionsNumber of Relay OutputRelay TypeContact RatingRS 485 Type
SW-BS-MA
2790027
9 to 32 V DC0.5ACurrent 4-20mA2.4 GHz4 Wireless Loadcells (Sum)2625-10°C to 50°C / 14°F to 122°F180 x 120 x 60mmN/AN/AN/AN/A
SW-BS-RLY
2790026
9 to 32 V DC0.5A2 relay outputs2.4 GHz4 Wireless Loadcells(Individual)2625-10°C to 50°C / 14°F to 122°F180 x 120 x 60mm2 (based on single set point)SPST (Relay 1 NO & Relay 2 NC)5 A at 250 VAC / 5 A at 30 VDCN/A
SW-BS-485-I
2789778
9 to 32 V DC0.5ARS-485 ASCII2.4 GHz4 Wireless Loadcells(Individual)2625-10°C to 50°C / 14°F to 122°F180 x 120 x 60mmN/AN/AN/AASCII
SW-BS-485-S
2789779
9 to 32 V DC0.5ARS-485 ASCII2.4 GHz4 Wireless Loadcells (Sum)2625-10°C to 50°C / 14°F to 122°F180 x 120 x 60mmN/AN/AN/AASCII
ModelStock No.Required Power SupplyOperational CurrentOutput Radio FrequencyMaximum Number of LoadcellsRange (m)Operating TemperatureDimensionsNumber of Relay OutputRelay TypeContact RatingRS 485 Type
SW-BS-MA
2790027
9 to 32 V DC0.5ACurrent 4-20mA2.4 GHz4 Wireless Loadcells (Sum)800-10°C to 50°C / 14°F to 122°F180 x 120 x 60mmN/AN/AN/AN/A
SW-BS-RLY
2790026
9 to 32 V DC0.5A2 relay outputs2.4 GHz4 Wireless Loadcells(Individual)800-10°C to 50°C / 14°F to 122°F180 x 120 x 60mm2 (based on single set point)SPST (Relay 1 NO & Relay 2 NC)5 A at 250 VAC / 5 A at 30 VDCN/A
SW-BS-485-I
2789778
9 to 32 V DC0.5ARS-485 ASCII2.4 GHz4 Wireless Loadcells(Individual)800-10°C to 50°C / 14°F to 122°F180 x 120 x 60mmN/AN/AN/AASCII
SW-BS-485-S
2789779
9 to 32 V DC0.5ARS-485 ASCII2.4 GHz4 Wireless Loadcells (Sum)800-10°C to 50°C / 14°F to 122°F180 x 120 x 60mmN/AN/AN/AASCII

The SW-BS provides a configurable analogue output for any single or summed group of up to 4 Crosby Straightpoint wireless load cells and is ideal for integration to a PC, PLC and other data acquisition. Housed in a IP65 enclosure, the output can be selected from Current 4-20mA, 2 Relay Outputs, RS485 ASCII
(Configurable) plus an optional CANbus 2.0A or 2.0B output.